Guide to Making a UTP RJ45 Network Cable
Guide to making a UTP RJ45 CAT5 network cable, straight-through or crossover, according to the EIA568A and B specifications. The crossover Ethernet cable (also called a cross cable or…
https://www.electronics-engineering.com/en/guide-to-making-a-utp-rj45-network-cable/

Guide to making a UTP RJ45 CAT5 network cable, straight-through or crossover, according to the EIA568A and B specifications.
The crossover Ethernet cable (also called a cross cable) is a type of twisted-pair Base-T Ethernet cable (like UTP cables or similar) with an 8-pin RJ-45 connector at each end, as in a normal straight Ethernet cable, but unlike that one the wires inside the cable do not connect each pin of one connector with the corresponding pin of the other connector.
Instead the wires are crossed, so that the transmit wire at one end of the cable becomes the receive wire at the other end, as shown in the following diagram:
| Wiring diagram according to the EIA/TIA T568B standard. |
|---|
| On connector 1, the White/Green wire corresponds to the White/Orange wire on connector 2. |
| On connector 1, the Green wire corresponds to the Orange wire on connector 2. |
| On connector 1, the White/Orange wire corresponds to the White/Green wire on connector 2. |
| On connector 1, the Blue wire corresponds to the Blue wire on connector 2. |
| On connector 1, the White/Blue wire corresponds to the White/Blue wire on connector 2. |
| On connector 1, the Orange wire corresponds to the Green wire on connector 2. |
| On connector 1, the White/Brown wire corresponds to the White/Brown wire on connector 2. |
| On connector 1, the Brown wire corresponds to the Brown wire on connector 2. |
Note: if the colours of the cable are different, just keep the correspondences right.
In Base-T Ethernet networks this type of cable is used to connect two network devices of the same type directly to each other (for example two PCs, two hubs). In Ethernet networks that use coaxial cables the concept of a crossover cable does not exist.
The speed of the crossover cable is identical to that of the straight one: 10, 100 or 1000 megabit/s depending on the standard used.
In the traditional configuration of an Ethernet local network the cables do not run from one computer to another; instead a cable runs from each computer to a common point, in a configuration called a star, and at this point there is a device (such as a hub or a switch).
When this connection method is used, you need a straight Ethernet cable (a patch cable) and the hub or switch takes care of making the appropriate connections. When instead two computers (or two devices of the same class) are connected directly with a single cable, the cable itself must provide the necessary wire swaps.
Connecting to a router is different: the router is treated like a PC and behaves in the same way as far as connections are concerned, so a router is connected to a PC with a crossover cable, while a straight cable is used to connect it to a switch.
Since crossover cables look exactly the same on the outside as straight ones, it is good practice to give them a different colour from the one used for straight cables. The colour normally used to distinguish crossover cables is red.
It is preferable for the whole outer jacket of the cable to be that colour. Failing that, to show that the cable is crossed you can use small red rings placed near the connectors. Failing those, it is still preferable to have some mark (such as adhesive labels) so that crossover cables can be recognised. Another method often used is to write the word cross or crossed among the technical data printed on the cable itself.
A crossover cable can be made from a normal UTP Cat.5 cable or similar by swapping the order of the transmit and receive pairs (orange and green) at one of the two connectors. The indicative cost of a 3 m patch cable is around 4 euros. The maximum length of a UTP, STP or FTP cable for a 10Base-T or 100Base-T connection is 100 metres. By convention, in structured cabling this installed length should be 90 m (plus the two patch cables of at most 5 m each.






Benvenuti nella pagina su «Guida al Montaggio di un Cavo di Rete UTP RJ4». L'ho scritta pensando a chi studia ingegneria elettronica: se un passaggio non vi torna, un esercizio vi dà un risultato diverso o volete altro materiale sull'argomento, chiedete pure nei commenti e vi risponderò. Un voto con le stelle qui sopra mi aiuta a capire quali pagine migliorare.